Z (0) A (1) B (2) C (3) D (4) E (5) F (6) G (7) H (8) I (9) J (10) K (11) L (12) M (13) N (14) O (15) P (16) Q (17) R (18) S (19) T (20) U (21) V (22) W (23) X (24) Y (25) Z (26) AA (27) AB (28) AC (29) AD (30) AE (31) AF (32) AG (33) AH (34) AI (35) AJ (36) AK (37) AL (38) AM (39) AN (40) AO (41) AP (42) AQ (43) AR (44) AS (45) AT (46) AU (47) AV (48) AW (49) AX (50) AY (51) AZ (52) BA (53) BB (54) BC (55) BD (56) BE (57) BF (58) BG (59) BH (60) BI (61) BJ (62) BK (63) BL (64) BM (65) BN (66) BO (67) BP (68) BQ (69) BR (70) BS (71) BT (72) BU (73) BV (74) BW (75) BX (76) BY (77) BZ (78) CA (79) CB (80) CC (81) CD (82) CE (83) CF (84) CG (85)
1 Consommation de chaleur 2021 Consommation de chaleur 2020 Consommation de chaleur 2019 Consommation de chaleur 2018 Consommation de chaleur 2017
2 Moyennes Corr. à 365 j. Totaux Détail Détail Détail Détail Détail
3 Mois Jan Fév Mar Avr Mai Jun Jul Aoû Sep Oct Nov Déc Mois Jan Fév Mar Avr Mai Jun Jul Aoû Sep Oct Nov Déc Mois Jan Fév Mar Avr Mai Jun Jul Aoû Sep Oct Nov Déc Mois Jan Fév Mar Avr Mai Jun Jul Aoû Sep Oct Nov Déc Mois Jan Fév Mar Avr Mai Jun Jul Aoû Sep Oct Nov Déc
4 Dates de relevé 44196.00 44227.00 44255.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Dates de relevé 43861.00 43890.00 43921.00 43951.00 43982.00 44012.00 44043.00 44074.00 44104.00 44135.00 44165.00 44196.00 Dates de relevé 43496.00 43524.00 43555.00 43585.00 43616.00 43646.00 43677.00 43708.00 43738.00 43769.00 43799.00 43830.00 Dates de relevé 43131.00 43159.00 43190.00 43220.00 43251.00 43281.00 43312.00 43343.00 43373.00 43404.00 43434.00 43465.00 Dates de relevé 42765.00 42793.00 42821.00 42856.00 42884.00 42912.00 42949.00 42975.00 43010.00 43038.00 43066.00 43096.00
5 Jours 59.00 31.00 28.00 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Jours 31.00 29.00 31.00 30.00 31.00 30.00 31.00 31.00 30.00 31.00 30.00 31.00 Jours 31.00 28.00 31.00 30.00 31.00 30.00 31.00 31.00 30.00 31.00 30.00 31.00 Jours 35.00 28.00 31.00 30.00 31.00 30.00 31.00 31.00 30.00 31.00 30.00 31.00 Jours 34.00 28.00 28.00 35.00 28.00 28.00 37.00 26.00 35.00 28.00 28.00 30.00
6 Température extérieure moyenne (ISM Pully, °C) 4.06 2.21 5.92 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! Température extérieure moyenne (ISM Pully, °C) 4.16 7.21 7.35 13.18 15.41 17.40 21.55 21.37 17.76 10.91 8.05 4.42 Température extérieure moyenne (ISM Pully, °C) 2.13 4.49 7.93 10.22 11.76 19.52 22.53 20.41 17.11 13.52 7.24 5.74 Température extérieure moyenne (ISM Pully, °C) 5.53 1.29 4.91 13.40 15.34 19.35 22.30 22.35 18.34 13.05 7.46 5.15 Température extérieure moyenne (ISM Pully, °C) -0.63 5.46 8.56 10.93 14.42 21.20 20.78 20.85 15.46 13.03 6.56 2.56
7 DJC [20/12] 5903.32 954.24 477.12 477.12 477.12 477.12 477.12 477.12 477.12 477.12 477.12 477.12 477.12 477.12 DJC [20/12] 416.52 416.52 416.52 416.52 416.52 416.52 416.52 416.52 416.52 416.52 416.52 416.52 DJC [20/12] 479.62 479.62 479.62 479.62 479.62 479.62 479.62 479.62 479.62 479.62 479.62 479.62 DJC [20/12] 422.31 422.31 422.31 422.31 422.31 422.31 422.31 422.31 422.31 422.31 422.31 422.31 DJC [20/12] 701.40 399.10 313.40 203.80 112.20 0 0 0 44.20 70.20 376.20 523.30
8 #REF! 0 0 #REF! #REF! #REF! #REF!
9 #REF! 0 0 #REF! #REF! #REF! #REF!
10 #REF! 0 0 #REF! #REF! #REF! #REF!
11 Selon factures 2021 (59 j) Selon factures 2020 Selon factures 2019 Selon factures 2018 Selon factures 2017
12 Bât. Admin. MWh 44.08 545.42 88.16 50.66 37.50 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 40.54 31.14 29.69 11.09 8.65 5.00 0.18 1.31 4.73 21.71 27.91 42.83 Bât. Admin. 50.78 36.88 31.48 21.41 18.14 3.72 0.40 1.69 6.06 16.12 33.55 38.68 Bât. Admin. 39.37 49.27 47.79 12.27 9.25 1.89 0.14 1.19 4.43 17.93 32.69 41.87 Bât. Admin. 62.91 34.17 24.68 22.07 10.50 0.03 0.03 0.03 10.82 13.80 32.67 44.51
13 Bât. Admin. Fr. HTVA 78.540 /MWh 42837.11 6924.35 3978.90 2945.45 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 3183.69 2445.40 2331.78 870.65 679.40 393.00 14.43 102.85 371.87 1704.90 2192.31 3363.78 Bât. Admin. 3988.02 2896.25 2472.24 1681.73 1424.72 292.41 31.25 132.80 476.29 1266.16 2634.94 3037.71 Bât. Admin. 2942.53 3682.16 3571.98 946.87 713.85 145.71 10.66 91.72 342.00 1408.11 2567.75 3288.75 Bât. Admin. 3979.56 2161.40 1561.13 1395.83 663.98 1.71 2.15 1.77 684.16 905.98 2145.31 2922.26
14 Total Fr. HTVA 1.160 /MWh 49704.06 8034.35 4533.90 3500.45 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Total 3738.69 3000.40 2886.78 1425.65 1234.40 948.00 569.43 657.85 926.87 2259.90 2747.31 3918.78 Total 4543.02 3451.25 3027.24 2236.73 1979.72 847.41 586.25 687.80 1031.29 1821.16 3189.94 3592.71 Total 3497.53 4237.16 4126.98 1501.87 1268.85 700.71 565.66 646.72 897.00 1963.11 3122.75 3843.75 Total 4804.56 2986.40 2386.13 2220.83 1488.98 826.71 827.15 826.77 1509.16 1730.98 2970.31 3747.26
15 Valeurs corrigées à 30 jours 2021 (60 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2020 (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2019 (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2018 (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2017 (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j)
16 Bât. Admin. MWh 89.21 49.03 40.18 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45 Bât. Admin. 49.14 39.51 30.46 21.41 17.55 3.72 0.39 1.64 6.06 15.60 33.55 37.43 Bât. Admin. 33.75 52.79 46.25 12.27 8.96 1.89 0.13 1.15 4.43 17.35 32.69 40.52 Bât. Admin. 55.51 36.61 26.44 18.91 11.25 0.03 0.03 0.03 9.27 14.78 35.01 44.51
17 Bât. Admin. Fr. HTVA 7006.39 3850.55 3155.84 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3859.38 3103.12 2392.49 1681.73 1378.76 292.41 30.24 128.52 476.29 1225.32 2634.94 2939.72 Bât. Admin. 2522.17 3945.17 3456.75 946.87 690.82 145.71 10.31 88.76 342.00 1362.69 2567.75 3182.66 Bât. Admin. 3511.38 2315.79 1672.64 1196.43 711.40 1.83 1.74 2.04 586.42 970.69 2298.55 2922.26
18 Total Fr. HTVA 79379.67 61645.19 17734.49 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Total 26953.38 12483.74 11780.19 3245.03 2403.67 1634.79 792.89 923.47 1565.67 6214.39 10238.42 26601.97 Total 64112.47 23063.22 11458.43 6567.87 5048.37 1302.59 780.54 1011.00 1808.22 4040.27 13211.88 18792.01 Total 18969.07 98593.08 25233.98 3361.57 2482.19 1086.37 760.97 868.14 1467.29 4511.22 12557.96 22369.77 Total -229002.40 16406.67 8361.91 6093.22 3097.43 1169.87 1194.09 1189.38 2928.51 3986.89 13574.86 43970.50
19 Valeurs corrigées à 30 jours 2020® (60 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2020® (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2020® (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2020® (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Valeurs corrigées à 30 jours 2020® (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j)
20 Bât. Admin. MWh 436.00 71.44 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45 Bât. Admin. 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45 Bât. Admin. 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45 Bât. Admin. 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45 Bât. Admin. 39.23 32.21 28.73 11.09 8.37 5.00 0.18 1.27 4.73 21.01 27.91 41.45
21 Bât. Admin. Fr. HTVA 34243.67 5610.72 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28
22 Différences 2021 ÷ 2020® (Val. corr. à 30 j.) (60 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Différences 2020 ÷ 2020® (Val. corr. à 30 j.) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Différences 2019 ÷ 2020® (Val. corr. à 30 j.) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Différences 2018 ÷ 2020® (Val. corr. à 30 j.) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) Différences 2017 ÷ 2020® (Val. corr. à 30 j.) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j) (30 j)
23 Bât. Admin. MWh 109.41 17.77 9.80 7.97 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 0 0 0 0 0 0 0 0 0 0 0 0 Bât. Admin. 9.91 7.30 1.73 10.33 9.18 -1.28 0.21 0.37 1.33 -5.41 5.64 -4.02 Bât. Admin. -5.48 20.58 17.52 1.19 0.58 -3.11 -0.04 -0.12 -0.30 -3.66 4.78 -0.92 Bât. Admin. 16.28 4.40 -2.29 7.83 2.87 -4.97 -0.15 -1.23 4.54 -6.22 7.09 3.06
24 Bât. Admin. Fr. HTVA 8593.44 1395.67 769.56 626.11 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 0 0 0 0 0 0 0 0 0 0 0 0 Bât. Admin. 778.38 573.40 135.93 811.08 721.28 -100.59 16.27 28.99 104.42 -424.59 442.63 -315.56 Bât. Admin. -558.82 1415.44 1200.19 76.23 33.34 -247.29 -3.65 -10.77 -29.87 -287.22 375.44 -72.61 Bât. Admin. 430.38 -213.94 -583.92 325.78 53.92 -391.17 -12.22 -97.49 214.55 -679.21 106.24 -333.01
25 Coûts 2021 base 2020® (78.540 /MWh) Coûts 2020 base 2020® (78.540 /MWh) Coûts 2019 base 2020® (78.540 /MWh) Coûts 2018 base 2020® (78.540 /MWh) Coûts 2017 base 2020® (78.540 /MWh)
26 Bât. Admin. Fr. HTVA 34710.39 5610.72 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28 Bât. Admin. 3080.99 2529.73 2256.56 870.65 657.49 393.00 13.97 99.53 371.87 1649.90 2192.31 3255.28
27 Economies brutes (Val. corr. à 30 j.; 78.540 /MWh) Economies brutes (Val. corr. à 30 j.; 78.540 /MWh) Economies brutes (Val. corr. à 30 j.; 78.540 /MWh) Economies brutes (Val. corr. à 30 j.; 78.540 /MWh) Economies brutes (Val. corr. à 30 j.; 78.540 /MWh)
28 Bât. Admin. Fr. HTVA -0.25 -8634.24 -1395.67 -769.56 -626.11 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 0 0 0 0 0 0 0 0 0 0 0 0 Bât. Admin. -778.38 -573.40 -135.93 -811.08 -721.28 100.59 -16.27 -28.99 -104.42 424.59 -442.63 315.56 Bât. Admin. 430.59 -1616.02 -1375.94 -93.41 -45.88 244.65 3.47 9.16 23.67 287.22 -375.44 72.61 Bât. Admin. -1278.53 -345.43 179.91 -614.77 -225.75 390.73 11.80 96.99 -356.19 488.80 -557.12 -240.23
29 2021 base 2020® (59 j) 2020 base 2020® 2019 base 2020® 2018 base 2020® 2017 base 2020®
30 Bât. Admin. MWh 495.31 80.06 47.49 32.57 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! Bât. Admin. 41.48 30.02 31.66 13.28 8.22 4.61 0.12 1.10 4.34 20.71 28.56 40.68 Bât. Admin. 47.74 36.55 29.89 22.10 18.07 2.40 0.19 0.46 4.06 12.72 30.96 36.63 Bât. Admin. 42.07 45.45 39.18 13.00 8.14 0.65 0.12 0.56 2.81 14.10 30.31 38.42 Bât. Admin. 61.66 61.66 61.66 61.66 61.66 61.66 61.66 61.66 61.66 61.66 61.66 61.66
31 Différences MWh 0.10 50.10 8.10 3.17 4.93 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Différences -0.94 1.11 -1.97 -2.19 0.43 0.39 0.06 0.21 0.39 1.00 -0.64 2.15 Différences 3.03 0.32 1.59 -0.69 0.07 1.32 0.21 1.23 2.00 3.40 2.59 2.05 Différences -2.70 3.82 8.61 -0.72 1.12 1.24 0.02 0.63 1.63 3.83 2.38 3.45 Différences 1.24 -27.50 -36.99 -39.60 -51.17 -61.64 -61.63 -61.64 -50.85 -47.87 -28.99 -17.16
32 Coûts 2021 base 2020® (78.540 /MWh) Coûts 2020 base 2020® (78.540 /MWh) Coûts 2019 base 2020® (78.540 /MWh) Coûts 2018 base 2020® (78.540 /MWh) Coûts 2017 base 2020® (78.540 /MWh)
33 Bât. Admin. Fr. HTVA 38901.96 6288.26 3730.21 2558.05 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! Bât. Admin. 3257.64 2357.92 2486.38 1042.63 645.39 362.11 9.50 86.62 341.17 1626.23 2242.79 3195.25 Bât. Admin. 3749.71 2870.76 2347.57 1735.90 1419.57 188.35 14.94 35.95 319.21 999.26 2431.51 2877.08 Bât. Admin. 3304.01 3569.49 3077.49 1020.90 639.17 51.22 9.50 43.77 220.32 1107.64 2380.82 3017.45 Bât. Admin. 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11 4843.11
34 Economies estimées (78.540 /MWh) Economies estimées (78.540 /MWh) Economies estimées (78.540 /MWh) Economies estimées (78.540 /MWh) Economies estimées (78.540 /MWh)
35 Bât. Admin. Fr. HTVA -0.10 -3935.15 -636.09 -248.69 -387.40 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! Bât. Admin. 73.94 -87.48 154.60 171.98 -34.01 -30.89 -4.93 -16.23 -30.70 -78.67 50.48 -168.54 Bât. Admin. -238.31 -25.49 -124.67 54.17 -5.15 -104.06 -16.31 -96.85 -157.07 -266.90 -203.43 -160.63 Bât. Admin. 211.87 -299.88 -676.09 56.84 -87.64 -97.13 -1.35 -49.61 -127.89 -300.47 -186.93 -271.30 Bât. Admin. -97.69 2159.63 2904.90 3110.12 4018.75 4840.99 4840.44 4840.91 3993.70 3759.41 2276.97 1347.61
36 Part tarif été courant 88482.00 #VALUE! #VALUE! #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Part tarif été courant #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été courant #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été courant #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été courant #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
37 Part tarif été sans interv. 88482.00 #VALUE! #VALUE! #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Part tarif été sans interv. (30.12-->Format non prévu) #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été sans interv. (30.12-->Format non prévu) #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été sans interv. (30.12-->Format non prévu) #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! Part tarif été sans interv. (30.12-->Format non prévu) #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
39 Prix moyens
40 Bât. Admin. 78.54 78.54 78.54 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A Bât. Admin. 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 Bât. Admin. 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 78.54 Bât. Admin. 74.74 74.74 74.74 77.14 77.14 77.14 77.14 77.14 77.14 78.54 78.54 78.54 Bât. Admin. 63.26 63.26 63.26 63.26 63.26 63.26 63.26 63.26 63.26 65.66 65.66 65.66
44 Bât. Admin.